A: The sharkbite fittings will handle 200 degrees fine, but PEX is limited to 180 degrees at its rated pressure, and not to exceed 200 degrees. Push-to-Connect x FIP Brass Adapter Fitting is the fastest way to connect PEX, Copper, CPVC, PE-RT, or HDPE pipe in any combination. Non-Barrier PEX is intended for hot and cold domestic water use. While this channel may earn minimal sums when the viewer uses the links, the viewer is in NO WAY obligated to use these links. This product includes 2 color coordinated crimp rings - the included black crimp ring is intended for PEX while the copper-colored crimp ring is for use on polybutylene pipe. My heating system is boiler + hot water with baseboard fins and copper pipes. Can SharkBite fittings be used with soft copper or rolled copper? 2023 SharkBite fittings are certified for use with: No. SharkBite 3/4 in. The last thing you want is for your fitting to blow out under high pressure! Pipe insertion depths for SharkBite fittings vary dependingon the size of the fitting. We play games, we experiment, and we have FUN here, talking and learning about all things plumbing! Gear We Use:Coolest Clock Ever - https://amzn.to/31CjLkWMain camera - https://amzn.to/2RCyj1FLens for main and Second cameras - https://amzn.to/2SM7Second camera - https://amzn.to/2SdzfdQMy microphone - https://amzn.to/2FEvN8sXLR Interface - https://amzn.to/2RDqskjWireless Lav Mic - https://amzn.to/2HenuRpTripod to hold our camera - https://amzn.to/32aI7DjOur studio lights - https://amzn.to/2Zv2R6O*NOTE: This description contains affiliate links that allow you to find the items mentioned in this video and support the channel at NO COST TO YOU. A great example is a heat gun. It is also recommended to pressure test the system prior to sealing up the wall. of solder per joint. Some of these include: It has superior characteristics: elastic and thermal memory. But I thought maybe I should try out an ultrasonic clamp-on flow monitor on my main water pipe first. You can't install PEX in high heat areas like near recessed lighting. It is flexible, resistant to scale and chlorine. Soldered = copper pipe fittings. Picture 5: Sharkbite Coupling Fitting attached to the end of a 1/2 inch Copper Pipe Hot Water. Add to Wish List. Yes, but the heat transfer properties and operating temperatures are different. Above, Paul Pollets states that near-boiler fittings "should be soldered, pressed or screwed". Another method is to solder in a tee and a PEX supply adapter. SharkBite fittings and PEX pipe carry a 25-year warranty against any manufacturers defect as long as the item has been installed in accordance with the installation instructions and complies with local code. The regular potable water PEX will get air in it and rust your heating hardware. Yes, SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F. FIP x 18 in. More on this later.) It has developed a leak and I was wondering if it is better to use Pex or stick with the copper. If I remember correctly sharkbites are rated at 240 deg. 1. Your email address will not be published. PEX pipe doesnt require the use of glue or cement, can be air tested and can be installed in wet or dry conditions. So now that push fittings have been thrown out, what is best? I did this for two reasons: after consulting the product guides for the particular brand of PEX I used with an oxygen barrier it did not say crimp rings were approved for use and because sharkbites are full-port whereas most PEX connections go inside the tube, which is already smaller diameter than their copper nominally-sized counterparts. The tube liner can easily be removed by pulling it past the o-ring, with theaid of the SharkBite Disconnect Clip or Disconnect Tongs (both sold separately). Can I use SharkBite fittings for hydronic heating? These colors are just for your convenience. Can PEX pipe be joined with solvent cement? Parallel runs of pipe can be spaced as close as necessary. What types of pipe can SharkBite fittings be used with? If it wasnt clean and smooth when it was originally inserted into the sharkbite fitting it might have been hard for the oring to seal or the teeth to seat properly, which may have in turn been the cause of failure. These Fittings are perfect for the do it yourselfer or the season pro. When water freezes, it expands and creates pressure that exceeds plumbing system pressure capabilities, i.e. List of materials needed for a project like this (Click Link below to Purchase Product and see more Information), QuantityX - Cash Acme Sharkbite Ball Valves, QuantityX - Sharkbite Plumbing and Heating Quick Connections Fittings, QuantityX - Cash Acme SharkBite Accessories and Tools, QuantityX - SharkBite Flexible Coupling Hoses for Water Heaters, QuantityX - Plumbing PEX Tubing, Tools and PEX Plumbing Accessories, X = Various Amounts of Product needed - dependant on actual system, 2000 - 2023 Houseneeds, Inc. 131 S Main Street Suite 1, Barre Vermont 05641 (802) 583-2726, Condensing Boiler 3" Concentric Termination Kit, Sharkbite Plumbing and Heating Quick Connections Fittings, Cash Acme SharkBite Accessories and Tools, SharkBite Flexible Coupling Hoses for Water Heaters, Plumbing PEX Tubing, Tools and PEX Plumbing Accessories, View all Radiant PEX Tubing and Accessories, View all PEX Plumbing Tubing and Accessories, View SharkBite Flexible Coupling Hoses for Water Heaters. 2023 The tube support liner can drop out of the fittings as it can move freely past the grab ring. the expansion fitting has a better chance of shrinking back down to its original configuration if it freezes as well, freezing could tend to push a crimp ring off or cut the tubing on the crimp ring. In Stock. Read more about behind-the-wall applications. All Rights Reserved. pex is a pain for tight corners. Another thing I was warned about reading online was PEX expansion. My boiler manual recommends a temp setting of 200 degrees for baseboards and convectors. The pipe must be cut square, deburred and free of debris before installing. The large diameter tube liners are sold separately. Most professional plumbers believe that SharkBite fittings and other kinds of push-fit fittings should only be used as an emergency, temporary fix, and not for any enclosed or permanent plumbing system. PEX Tubing is a cross-linked polyethylene pipe manufactured using extrusion method. The SharkBite system includes couplings, elbows, tee fittings, ball valves, stop valves, male and female adapters, conversion couplings, fitting reducers, and an assortment of faucet, toilet,. Designed for use on hot and cold potable water lines, Orange PEX tubing is commonly used for radiant floor and hydronic heating applications. Keep the PEX pipe a minimum of 12 in. Use Pex-Al-Pex instead..it's aluminum sheath will keep the pipe in shape, and it has about the same expansion characteristics as copper. Can I use SharkBite fittings on baseboard heat? My story is a single occurrence. screwed= threaded fittings. So I went to the store, bought a torch, a flux/solder kit, and two copper fittings. A community dedicated to helping people with advice on personal home improvement projects. On Saturday morning at 4:19 am I was fast asleep. So I will be trying that out and will report back. Thus, even though lots of people say theyve had good experiences with these kinds of push-to-connect fittings, I have to recommend against them, especially in extra-hot water situations. It's that easy. In cases where PEX pipe penetrates a concrete slab, it must be protected with a nonmetallic sleeve at the penetration point. Yes, SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F. Different types of air compressors use different types of fittings. . Today I'm telling you why I don't use Sharkbites and why I don't let my plumbers use them either. Something about them just makes me nervous. SharkBite PEX pipe meets NSF/ANSI Standard 61, and is approved for drinking water systems. Yes, Sharkbite fittings can be used for compressed air. So if youre using them for compressed air, make sure the pressure is not too high. *See warranty information for limited warranty details. What is the maximum temperature and pressure rating for SharkBite fittings? I've seen someone try to use press fittings on a steam generator. PEX pipe is made from cross-linked HDPE (high density polyethylene). Finally, always test your connections before putting your system into service. Near boiler piping should be in black or at least copper. pressed= copper fittings with an O-ring seal that get pressed on the pipe = sharkbite that needs a special tool. Press question mark to learn the rest of the keyboard shortcuts. Most hot water systems run great at 170-180. The Pellet Mill - Pellet and Multifuel Stoves, Central Boiler OWB Overheat/Not Circulating Troubleshooting Help. Can I use SharkBite fittings as a dielectric union? What are the differences in the red, white, blue, gray and orange PEX pipe? It is recommended to solder any joints prior to installing a SharkBite fitting. x 100 ft. Yes, PEX pipe is freeze-damage resistant. SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F. Click Here for more info. Today I'm telling you why I don't use Sharkbites and why I don't let my plumbers use them either. It is durable and can withstand high pressure, making it ideal for use in pneumatic tools and other equipment. pipes and fittings burst. I figured if one develops a leak all of my piping is exposed so I can get to it and replace it with another pretty easily. For 1/2-in. Black iron pipe is also generally quite affordable, which makes it a popular choice among many DIYers and small businesses. There are also a lot of plumbers like me who will never use Sharkbites on our plumbing work. In some jurisdictions those things aren't permitted anywhere. But can they be used for compressed air? Whether you're working with PEX, Copper, or CPVC, AquaLock has you covered . SharkBitefittings can be reused for testing purposesbut any fitting used repeatedly for testing should not be used in a permanent installation. Sharkbite fittings are a type of fitting that can be used with hydronic heating systems. Yes, you can use SharkBite fittings on hot water lines. Are SharkBite fittings certified for hydronic heating applications? Learn more: SharkBite Warranty. RWC applications? Water systems should not be allowed to freeze. Braided Stainless Steel Water Heater Connector with Integrated Ball Valve located in New Prague, MN in . It can also be used in domestic water applications because it meets the NSF/ANSI/CAN 61 standard. PEX-A: Peroxide This method employs organic peroxides that, when heated, generate reactive free radicals that splice PEX chains together during extrusion, PEX-B: Silane This method involves grafting a reactive silane molecule to the backbone of the polyethylene, PEX-C: Electron beam This method involves subjecting the extruded PE pipe to a dose of high-energy electrons. They will not work with PVC or other types of piping. Another possible disadvantage to using SharkBite fittings is that many plumbers feel that these fittings simply aren't strong enough to create a tough, durable connection. When combined with our push-to-connect fittings, manifolds, valves and other supplies, PEX pipe offers the fastest way to plumb any project. Where is PEX pipe approved for plumbing use? What make model? I wonder why that thing is going off?. In general, 5/8" PEX will feed loops that would normally be run in 3/4" copper. If you have any questions about how to do it, let me know. Castile exhaust blower housing replacement woes ! Once youre satisfied that everything is secure, go ahead and turn on the compressor and enjoy the convenience of having SharkBite fittings in your shop! The HDPE is melted and continuously extruded into a tube to form a high-performing pipe suitable for a variety of potable and non-potable plumbing applications. Or is "expansion fitting" synonymous with a fitting that is 'pressed' ? Find many great new & used options and get the best deals for SHARK BITE 25482Z 4-PORT HYDRONIC HEATING MANIFOLD 1" SWT X 1/2" PEX at the best online prices at eBay! I used sharkbites in my baseboard hot-water heating. cost effective than copper. PEX is short for cross-linked polyethylene. I've got one on a hot water line and no leaks. I touched it gently and it started dropping. Plumbing fittings are not typically used for air compressors, as the two systems operate using different principles. Here's why.Follow me on the Socials! Corrosion increases dramatically at higher temperatures. Do I need the Disconnect Clip to remove a SharkBite fitting? Instead, theyre only meant to be used with non-potable water systems like irrigation or pool systems. PEX pipe will expand if frozen and contract to its original shape when thawed. I didn't say I'd use them -- I wouldn't -- but only that he's within the manufacturer's spec. Apollo PEX fittings may be used with copper crimp rings, stainless steel pinch clamps or stainless steel crimp sleeve (all sold separately). Oxygen Barrier and PEX-AL-PEX tubing are intended for closed-loop heating applications (radiant floor heat, baseboards, etc.) Yes, Sharkbite fittings can be used for compressed air. This composition makes SharkBite fitting ideal for potable water distribution and hydronic heating. Sharkbite would be ok away from the boiler. If you read the fine print on copper pipes, they say max temp of 180F, at least mine doesmakes you wonder. This is an off-brand version (Proline) of something commonly called a sharkbite connector. Supposed to install tomorrow so any input tonight would be great. Simple installation and ease of use make the SharkBite push-fit fittings and valves one of the fastest, easiest ways to plumb many residential or commercial jobs, and are easy to disconnect if needed. The rule of thumb has been to come off the boiler 10 feet with copper or iron before changing to PEX. SharkBite Water Heater Connector allows you to easily connect your Hot and Cold-Water Supply lines to your Water Heater.. SharkBite Compression Straight Stop Valve If still having issues, don't hesitate to contact our support team. PEX-A, which is a type of PEX, is a top choice for hydronic heating applications for so many reasons. Another thing to keep in mind is that Sharkbite fittings are not designed for high-pressure applications. Can I use PEX pipe for radiant or hydronic heat applications? I've come across an apparent contradiction.. background: I'm considering using oxygen-barrier PEX in an enhancement to my copper hydronic piping. I will be recovering the pipe with concrete when the leak is repaired. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register. Nice. Its a type of plastic that has been treated with chemicals to create stronger bonds between its molecules. The SharkBite push-to-connect range is made from Lead Free DZR Brass and all products were converted as of October 2012." This method doesn't require soldering, which can be a big time-saver. SharkBite Fittings are certified for potable water supply and hydronic heating applications. https://linktr.ee/rogerwakefieldThanks for watching! Can I use PEX pipe for compressed air applications? Froling 40/50 ,150 gal.buffer tank,1000 gal. SharkBite 1/2 in. of lead-free silver solder and bend it at 90 about 2 in. If you continue to use this site we will assume that you are happy with it. A SharkBiteDisconnect Clip orDisconnect Tongs are required to remove a SharkBite fitting. SharkBite fittings canleak due to one of thesereasons: Review installation instructions to ensure you've followed the correct steps. Will really make job a lot easier but would like input from others that may have tried this first. All SharkBite Push-To-Connect fittings can withstand up to 200 PSI and 200 degrees Fahrenheit. About the PEX you want to use. If youre in the market for a new compressed air system, you may have come across the term PEX. But what is PEX, and why is it a good choice for compressed air? Soldered joints are permanent, and they create a seamless connection between the two pipes. PEX pipe is flexible and can be navigated around obstacles. Please make sure that the pipe is not exposed to direct UV rays. and Push (sharkbite) but that one has already bee defunked. The Infopanel: a simple MQTT-connected display system for weather, traffic, pictures, animationsanything! Click to see full answer. Tube liners are not required when using SharkBite large diameter fittings with copper or CPVC. Up-to-date pipe insertion depths can be found here. That's 2 votes for pex now. For 1/2" PEX with OD of 5/8", minimum bending radius is 8 x 5/8" = 5". When you insert the pipe, the stainless steel teeth in our push-to-connect fittings bite down and grip tight, while the specially formulated o-ring compresses to create a perfect, secureseal. For example, "SharkBite Push-to-Connect Fittings. Can you connect polybutylene to copper? The 1/2-in SharkBite . SharkBite PEX Barb fittings are compatible for potable water distribution and hydronic heating applications. Hello - Yes, brass SharkBite Push-to-Connect fittings are suitable for radiant/hydronic heating. I used sharkbites in my baseboard hot-water heating. Yes, PEX pipe can save money in numerous ways. SharkBite fittings are actually designed for use with both water and gas, so they can easily handle the higher pressures associated with compressed air. I did this for two reasons: after consulting the product guides for the particular brand of PEX I used with an oxygen barrier it did not say crimp rings were approved for use and because sharkbites are full-port whereas most PEX connections go inside the tube, which is already smaller diameter than their copper nominally-sized counterparts. IN THE GARAGE! It doesn't NEED to be in a sleeve, but the slab will suck some heat out of it as it passes through, and 180 water shouldn't really be run in concrete. Is an "expansion fitting" yet another kind of fitting ?? you have to be careful how you put a crimp ring on and that the tooling is well made and in good condition to get a mostly even grip. Braided Stainless Steel Water Heater Connector The 1/2 in. Hydronic heating is a type of radiant heating that uses water to heat your home. Granted, these fittings were not in your normal hot water heater setup. Apollo PEX fittings are suitable for both potable water and hydronic heating systems. Does SharkBite PEX piping affect drinking water quality? Second, be sure to use an appropriate size fitting for your application. VEVOR Oxygen Barrier PEX Tubing - 1/2 Inch X 900 Feet Tube Coil - EVOH PEX-B Pipe for Residential Commercial Radiant Floor Heating Pex Pipe (1/2\" O2-Barrier, 900Ft/Red) (37) C $30899. Upon opening the door, there was steam and water just rushing out near the hot water heater. You can connect Sharkbite push-fit fittings to copper tubing, CTS, CPVC, and PEX. It currently has baseboard heating but it runs right through where I am going to be putting an opening for a door. PEX pipe should not be stored in direct sunlight. Thats because these particular fittings are not approved for use with drinking water. They can even be rotated after assembly for easier installation in tight spaces. What standards & codes do SharkBite fittings comply? . The red PEX pipe is intended for domestic water applications only. horizontally from sources of high heat such as recessed light fixtures, gas flue vents, heating appliances or electric motors. I'm Roger Wakefield, The Expert Plumber, and welcome to my channel. Soany advice you have on pex choice type (pex-al-pex vs general o2 barrier pex, pex a vs pex b, as well as information on PERT being an option) and possibly even brands Uponor, Sioux Chief, Nibco, Watts etc would be appreciated. Yes. However, SharkBite Stainless Steel Braided Flexible Coupling Hoses can be used as a dielectric union. The teeth are there but a huge fraction of them have totally just corroded away! A quick way to do this is to use a soapy water solution; if there are any leaks, the bubbles will show you where they are. If you're a homeowner, you've probably seen SharkBite fittings. I use a special electric soldering clamp for all the soldering I do, since I work in old to very old structures where using a torch just isn't a good thing. This makes PEX more resistant to heat and pressure than regular polyethylene. The kit features a 6-loop SharkBite radiant manifold, a Cash Acme TMV, SharkBite oxygen barrier PEX and fittings, thermostat, and a circulating pump with an integrated relay. Orange PEX pipe is an oxygen barrier PEX pipe used only for hydronic heating applications. The single neoprene o ring in the fitting is the only thing keeping the connection from leaking. If you continue to use this site we will assume that you are happy with it. If you do this, you MUST use the PEX that has an oxygen barrier. While the materials, fittings, and sleeves for PEX A and PEX B can fluctuate, PEX B is the overall cheaper material. So I staggered down to the garage on the first level. PEX pipe can be pressurized for testing as soon as all necessary connections have been made. I also figured that even if they don't last 30 years, I haven't heard of a catastrophic failure of a Sharkbite brand (off-brands yes) fitting. The Mechanics of a SharkBite Like many of the most helpful inventions, SharkBite fittings are both brilliant yet deceptively simple. Steadily, they're becoming more trusted as their longevity and reliability continue. On this channel, it's ALL about plumbing. What is the maximum temperature and pressure rating for SharkBite fittings? Plumbing relies on gravity to move water through pipes, while air compressors rely on electrical power to compress and move air through hose lines. SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F. When SharkBite PEX pipe and fittings are used together, the labor . Crimp or expansion? Lets take a look at those teeth. I know lots of people on the internet totally live by push-to-connect plumbing fittings. Differences can be summarized as follows: Red PEX pipe This is designed specifically for heating systems and has a metal liner inside to prevent air from permeating in. pressed= copper fittings with an O-ring seal that get pressed on the pipe = sharkbite that needs a special tool. For more information, read our full SharkBite Warranty. Download now: Homeowners Comparison: PEX v. Copper, PEX pipe is easier to install than rigid pipe, and it is available in long coils which can eliminate the need for extra fittings. SharkBitefittings can be rotated after installation. What types of pipe can SharkBite fittings be used with? SharkBite PEX barb fittings are compatible for potable water distribution and hydronic heating applications. 62K views 4 years ago #homerepair In this video we show you how to replace an existing heating element with a new one using Shark Bite fittings. But it really happened and you can see for yourself the corrosion. SharkBite PEX pipe is very difficult to uncoil, what is the best method for achieving this? Do I need tools to connect SharkBite fittings? Hello all, I am renovating my second floor attic/bedrooms in my Gambrel Cape. Coupling, Elbow, Tee) cannot be used as a dielectric union. There are two, actually three types of fitting for PEX pipe. SharkBite is one common brand of stab-in fitting. Color-Coded: Red PEX pipes can be used for hot water supply lines, blue PEX for cold water supply, and white for either hot or cold. What is the difference between PEX-A, PEX-B and PEX-C? RWC PEX pipe doesnt corrode or develop pinholes. Orlan EKO 40, Forced Air Furnace HX - Sold to a good home. PEX can withstand high temperatures and pressures. What can I text my friend to make her smile? If you have any more questions you can call tech . As a follow up did you use sharkbite for your pex or soldered connections. Copyright 2022 Toolsideas - All rights reserved. I just kept my fittings a sufficient distance from the heat source (stove) so that the fitting did not exceed 240 via radaint heat transfer. SharkBite 3/4 in. Since PEX pipe is supplied in coils, installation can be completed in one continuous length without the need for extra fittings. For automation and alerts, long-time readers of this blog will know Im using the inimitable Home Assistant system with lots of carefully hand-crafted automation. I don't trust the sharkbites for heating. Plumbing code does not require the pipe color to match the type of water supply. Learn about the application and use of SharkBite push-to-connect brass fittings. Designed and manufactured for many years of service life, AquaLock push-to-connect fittings are your first choice for reliability. Why do plumbers not like SharkBite fittings? Since ferrous components are likely to be present in the system, it is important to use oxygen barrier PEX pipe to help prevent ferrous components from rusting. SharkBite brass push fittings are approved by IAPMO for underground applications as long the fitting is wrapped with silicone tape. . I've looked at electric soldering a couple times for the same reasons. Sharkbite Priced $27.08 (compare at $28.50). (See this old post, which is desperate need of updating since I moved). But check with your plumbing inspector if you're planning to bury this connection in a wall or ceiling. SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F.NOTE: Glycol mixture for hydronic is acceptable up to and including 100%. Yes, SharkBite PEX pipe is approved to AWWA C904 which covers PEX pipe in regards to burial. L or M. I dont see any pictures of the inside of the pipe to see the wall thickness. PEX A Material: $0.35/foot 90 fittings: $1.00/each Sleeves: $0.15/each Tool: Milwaukee Automatic Expansion Tool, $250 That $38 or whatever saved thousands of dollars of water damage and a huge repair project. What kind of pipe did you use. Depends on the item. Those fittings should be soldered, pressed or screwed. SharkBite push-to-connect fittings are the core products within the SharkBite System, and provide the easiest and most dependable way to join PEX, copper, CPVC, HDPE or PE-RT pipe in any combination without solder, clamps, unions or glue.